Basically, the ventilation can be designed even without having to carry out the ducts as the space between the ceiling girder can create ventilation ducts. The spaces themselves between the flat girders can create ventilation ducts. With such space, we can reduce airflow velocity up to 1 m/s thereby reducing the noise and the drag. By gaining a slight overpressure within the ceiling a large plenum is created. The structure of the suspended ceiling, e.g. a properly selected perforated plate, or even a fabric provides for a laminar flow of air over the entire floor area.
It can be said that the entire system was designed to solve out all the problems connected with conducting ventilation ducts and installing ventilation systems throughout the building. We have designed a special device based on an air-to-air heat pump that heats, cools and ventilates at the same time. In addition, everything fits in the ceiling space, and the device and the minimum number of ducts can be installed anywhere.
STEERING
Key to comfort and economy is the ease of control and responsiveness of the system. Our innovative control system only requires input of time, number of occupants and required temperature. The system will automatically adjust to the required amount of fresh air depending on the number of occupants. As it is a distributed system, the responsiveness is also rapid.
SUMMER'S VARYING TEMPERATURE DISTRIBUTION
PUMPING AIR OR HEAT FROM ZONES
WITH DIFFERENT TEMPERATURES
TARGET TEMPERATURE DISTRIBUTION WITHOUT USING
THE ENERGY REQUIRED FOR COOLING OR HEATING
SUMMER'S VARYING TEMPERATURE DISTRIBUTION
PUMPING AIR OR HEAT FROM ZONES
WITH DIFFERENT TEMPERATURES
TARGET TEMPERATURE DISTRIBUTION WITHOUT USING THE ENERGY REQUIRED FOR COOLING OR HEATING
INNOVATIVE HEATING-COOLING-VENTILATION SYSTEM
VENTILATION – SPRING
VENTILATION AND COOLING – SUMMER
Cooling 2/3 and ventilation 1/3 modes
VENTILATION AND DAYTIME HEATING – WINTER
Heating, cooling and ventilation in one unit
heating mode 2/3 and ventilation mode 1/3
VENTILATION
– SPRING
VENTILATION
AND COOLING
– SUMMER
Cooling 2/3
and ventilation 1/3 modes
VENTILATION
AND DAYTIME
HEATING
– WINTER
Heating, cooling
and ventilation in one unit
Heating mode 2/3
Ventilation mode 1/3
STEERING
Key to comfort and economy is the ease of control and responsiveness of the system. Our innovative control system only requires input of time, number of occupants and required temperature. The system will automatically adjust to the required amount of fresh air depending on the number of occupants. As it is a distributed system, the responsiveness is also rapid.